Fine Particulate Sampler

We are the Prominent leading manufacutuer and Supplier of Fine Particulate Sampler. For sampling of fine particulate, the offered fine particulate sampler is used in cement and chemical industry. By using cutting-edge machinery, the offered fine particulate sampler is manufactured in accordance to the highest set quality standards.

Dust Particulate Sampler APM 154

Dust Particulate Sampler APM 154
  • Dust Particulate Sampler APM 154
  • Dust Particulate Sampler APM 154
  • Dust Particulate Sampler APM 154
Get Best Quote
Approx. Price: Rs 55,000 / PieceGet Latest Price
Product Brochure

Product Details:

FrequencySingle Phase,50Hz AC
Diameter47 mm
Power SourceElectricity
AutomationAutomatic
Power requirementNominal 220 V
DisplayDigital

We have achieved widespread acclamation in manufacturing and supplying best quality Dust Particulate Sampler. These samplers have intensified use in keeping a keen eye on the level of air pollution causing particulates present in the ambient air. With the fabrication and design being made in accordance with current industrial guidelines, these samplers have the ability to produce accurate results for longer time span. Apart from this, we make the supply of our offered product in durable packaging at reasonable price tags.

Features:

 

  • PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA
  • Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature
  • Lower sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels
  • Critical Orifice maintains constant sampling rate of 1 m3/hour
  • Sampler can run continuously 28 hrs monitoring
  • Can be measured PM10 or PM2.5 at a time
  • Calibration Certificate for each instrument shall be provided with instruments
  • Compact and portable
  • Weight: Approx 25 Kg

Owing to its modular design, APM 154 can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411. Kindly refer to respective brochures of LES 411

· Size Selective inlets: Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor

· Flow Rate: Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system

· Sampling Time Record: 0 to 9999.99 hrs. recorded on a Time Totalizer

· Vacuum Pump: Diaphragm Pump

· Power requirement: Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety, a good earth connection is mandatory

· Automatic Sampling: 24 hrs programmable timer to automatically shut off the system after a pre-Control set time interval.

· Sample Volume: Dry Gas meter records the total air volume sampled

· Filter: Filter holder designed to accept any standard 47 mm diameter filter media

Warranty: One year
Request
Callback
Yes! I am Interested

Ambient Fine Particulate Sampler APM 154

Ambient Fine Particulate Sampler APM 154
  • Ambient Fine Particulate Sampler APM 154
  • Ambient Fine Particulate Sampler APM 154
  • Ambient Fine Particulate Sampler APM 154
Get Best Quote
Approx. Price: Rs 55,000 / PieceGet Latest Price
Product Brochure

Product Details:

UsageIndustrial
Sensor TechnologyLight Transmission
DisplayDigital
Power SourceElectronic
Frequency50 hz
Voltage220 V

We are preeminent firm highly influential in manufacturing and supplying Ambient Fine Particulate Sampler. These samplers are widely reckoned in the market for their excellent functionality and user-friendly controls. Widely used as an instrument for measuring the properties of particulates in the ambient air, our offered samplers are manufactured in compliance with current industrial norms. Moreover, with the aim of serving clients satisfactorily, we supply these samplers in different preferences as per their requirements.

Features:


  • PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA
  • Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature
  • Diaphragm Pump with a low noise
  • Lower sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels
  • Critical Orifice maintains constant sampling rate of 1 m3/hour
  • Sampler can run continuously 28 hrs monitoring
  • Low power consumption
  • Low weight essay to transport in field
  • Can be measured PM10 or PM2.5 at a time
  • Calibration Certificate for each instrument shall be provided with instruments
  • Compact and portable.
  • Weight: Approx 25 Kg.

 

Owing to its modular design, APM 154 can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411. Kindly refer to respective brochures of LES 411

 

  • Size Selective inlets: Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor
  • Flow Rate: Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system
  • Sampling Time Record: 0 to 9999.99 hrs. recorded on a Time Totalizer
  • Vacuum Pump: Diaphragm Pump
  • Power requirement: Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety, a good earth connection is mandatory
  • Automatic Sampling: 24 hrs programmable timer to automatically shut off the system after a pre-Control set time interval.
  • Sample Volume: Dry Gas meter records the total air volume sampled
  • Filter: Filter holder designed to accept any standard 47 mm diameter filter media
  • Warranty: One year
Request
Callback
Yes! I am Interested

Fine Particulate Sampler APM 154

Fine Particulate Sampler APM 154
  • Fine Particulate Sampler APM 154
  • Fine Particulate Sampler APM 154
  • Fine Particulate Sampler APM 154
Get Best Quote
Approx. Price: Rs 55,000 / PieceGet Latest Price
Product Brochure

Product Details:

Driven TypeElectric
DisplayDigital
AutomationSemi Automatic
Weight25 kg
Frequency50Hz
Voltage220 V, Single Phase

We are actively engaged in manufacturing and supplying superlative quality Fine Particulate Sampler. Extensively used in studying the levels of the particulate present in the air, these samplers have the high efficiency of producing best results for the long duration of time. Moreover, these are available with us in wide configurations for serving divergent needs of customers with the uttermost satisfaction.

Features:

  • PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA
  • Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature
  • Diaphragm Pump with a low noise
  • Lower sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels
  • Critical Orifice maintains constant sampling rate of 1 m3/hour
  • Sampler can run continuously 28 hrs monitoring
  • Low power consumption
  • Low weight essay to transport in field
  • Can be measured PM10 or PM2.5 at a time
  • Calibration Certificate for each instrument shall be provided with instruments
  • Compact and portable
  • Weight: Approx 25 Kg

 

Owing to its modular design, APM 154 can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411.

 

  • Size Selective inlets: Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor
  • Flow Rate: Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system
  • Sampling Time Record: 0 to 9999.99 hrs. recorded on a Time Totalizer
  • Vacuum Pump: Diaphragm Pump
  • Power requirement: Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety, a good earth connection is mandatory
  • Automatic Sampling: 24 hrs programmable timer to automatically shut off the system after a pre-Control set time interval.
  • Sample Volume: Dry Gas meter records the total air volume sampled
  • Filter: Filter holder designed to accept any standard 47 mm diameter filter media
  • Warranty: One year
Request
Callback
Yes! I am Interested

Air Monitoring Instruments APM 154

Air Monitoring Instruments APM 154
  • Air Monitoring Instruments APM 154
  • Air Monitoring Instruments APM 154
  • Air Monitoring Instruments APM 154
Get Best Quote
Approx. Price: Rs 55,000 / PieceGet Latest Price
Product Brochure

Product Details:

Driven TypeElectric
AutomationSemi Automatic
Diameter47 mm
DisplayDigital
Automation GradeAutomatic
Power220 V

Features:

  • PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA
  • Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature
  • Diaphragm Pump with a low noise
  • Lower sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels
  • Critical Orifice maintains constant sampling rate of 1 m3/hour
  • Sampler can run continuously 28 hrs monitoring
  • Low power consumption
  • Low weight essay to transport in field
  • Can be measured PM10 or PM2.5 at a time
  • Calibration Certificate for each instrument shall be provided with instruments
  • Compact and portable.
  • Weight: Approx 25 Kg.

APM-154 can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411.

  • Size Selective inlets: Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor
  • Flow Rate: Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system
  • Sampling Time Record: 0 to 9999.99 hrs. recorded on a Time Totalizer
  • Vacuum Pump: Diaphragm Pump
  • Power requirement: Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory
  • Automatic Sampling: 24 hrs programmable timer to automatically shut off the system after pre-Control set time interval.
  • Sample Volume: Dry Gas meter records the total air volume sampled
  • Filter: Filter holder designed to accept any standard 47 mm diameter filter media
  • Warranty: One year
Request
Callback
Yes! I am Interested

Air Pollution Monitoring Instruments APM 154

Air Pollution Monitoring Instruments APM 154
  • Air Pollution Monitoring Instruments APM 154
  • Air Pollution Monitoring Instruments APM 154
  • Air Pollution Monitoring Instruments APM 154
Get Best Quote
Approx. Price: Rs 55,000 / PieceGet Latest Price
Product Brochure

Product Details:

DisplayDigital
AutomationAutomatic
Diameter47 mm
Power SourceElectricity
Voltage220 V
Frequency50 Hz

We have achieved remarkable success in this domain by manufacturing and supplying best in class Air Pollution Monitoring Instruments. These instruments due to their reliable capability in providing accurate results for prolong time duration has made them much useful in analysis and monitoring of particulates in the air. We have with us wide stipulations of these instruments for supply to customers as per their requirements.

Features:

  • PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA
  • Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature
  • Lower sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels
  • Critical Orifice maintains constant sampling rate of 1 m3/hour
  • Sampler can run continuously 28 hrs monitoring
  • Can be measured PM10 or PM2.5 at a time
  • Calibration Certificate for each instrument shall be provided with instruments
  • Compact and portable

 

Owing to its modular design, APM 154 can be easily paired with a gaseous sampling attachment (for monitoring SO2, NOx, NH3, Ozone etc.) as gaseous sampling requires only a few LPM of air flow. This is possible through an attachable subsidiary unit LES 411. Kindly refer to respective brochures of LES 411

  • Size Selective inlets: Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor
  • Flow Rate: Constant sampling rate of 1 m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system
  • Sampling Time Record: 0 to 9999.99 hrs. recorded on a Time Totalizer
  • Vacuum Pump: Diaphragm Pump
  • Power requirement: Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety, a good earth connection is mandatory
  • Automatic Sampling: 24 hrs programmable timer to automatically shut off the system after a pre-Control set time interval.
  • Sample Volume: Dry Gas meter records the total air volume sampled
  • Filter: Filter holder designed to accept any standard 47 mm diameter filter media
  • Warranty: One year
Request
Callback
Yes! I am Interested

Handy Sampler

Product Price :Get Latest Price
Handy  Sampler
  • Handy  Sampler
  • Handy  Sampler
  • Handy  Sampler
Ask For Price
X

Explore More Products

View All Products




Reach Us
Horam Singh (Chief Executive)
Lata Envirotech Services
K-307, UPSIDC Industrial Area, Site -5, Kasna
Greater Noida - 201310, Gautam Buddha Nagar, Uttar Pradesh, India


Call Us


Send E-mail